ScrapBull
#1 Copper Wire
Non-Ferrous Copper

#1 Copper Wire

Grade: Barley (Wire Grade)Very High Tier

Clean uncoated unalloyed copper wire, minimum 1/16 inch diameter

Market Price EstimateUpdated Daily
$3,750/ MT
+265 (7.6%)vs yesterday
Verified specifications & market data

Certification Requirements

Required certifications, standards compliance, and verification protocols.

ISO 9001:2015
Scope

Copper wire collection, sorting, processing QMS

Certificate of Analysis
Content
  • Copper purity ≥99%
  • Lead content <0.05%
  • Zinc <0.5%
  • Other contaminants
  • Bare bright + diameter verification
XRF or Assay Report
Issued By
  • Independent certified lab
  • Fire assay recommended
#1 Wire Grade Verification
Requirement

Explicit: '#1 Copper Wire, ≥1/16" diameter, Cu ≥99%, Barley Grade'

Diameter Certification
Requirement

Explicit: 'Minimum diameter ≥1/16 inch (1.6mm) verified'

Insurance Certificate
Minimum Coverage

£3–5 million (high-value material)

Rejection Criteria

Conditions and thresholds that trigger immediate rejection or downgrading.

Wire diameter below minimum
Threshold

Any wire <1/16 inch (1.6mm) diameter

Action

Partial rejection (segregate undersized wire) or full rejection

Reason
  • Diameter Specification Defines #1 Wire Grade
  • Undersized = Different Specification
Insulation present
Threshold

Any visible plastic coating

Action

IMMEDIATE FULL REJECTION

Reason
  • Insulated Wire = Lower Grade
  • Bare Bright Requirement
Copper purity insufficient
Threshold

Cu <99.0%

Action

Full rejection or reclassification

Reason

Grade specification violation

Lead contamination excessive
Threshold

Pb >0.05%

Action

Full rejection or major credit

Reason

Critical refinery concern

Zinc contamination
Threshold

Zn >0.5%

Action

Full rejection or reclassification

Reason

Brass contamination

Solder present
Threshold

Any visible solder

Action

FULL REJECTION

Reason

Solder coating loses #1 wire status

Paint, varnish, coating
Threshold

Any visible coating

Action

FULL REJECTION

Reason

Coating loses bare bright requirement

Ferrous attachments
Threshold

Steel components

Action

Rejection unless removed

Reason

Ferrous contamination

Mixed metals contamination
Threshold

Brass/aluminum/non-copper >1%

Action

Full rejection

Reason

Grade violation

Radioactive contamination
Threshold

Any detectable

Action
  • Immediate Rejection
  • Radioactive Protocol
PCB or hazardous
Threshold

Any visible

Action
  • Full Rejection
  • Hazmat Protocol
Asbestos
Threshold

Any detectable

Action
  • Full Rejection
  • Hazmat Disposal
Cookie Notice