ScrapBull
#1 Heavy Copper
Non-Ferrous Copper

#1 Heavy Copper

Grade: Candy (Heavy Solids)Very High Tier

Clean copper solids, clippings, busbars, minimum 1/16 inch thick

Market Price EstimateUpdated Daily
$3,720/ MT
+245 (7.1%)vs yesterday
Verified specifications & market data

Chemical Composition

Elemental breakdown by percentage weight.

Standard composition limits
Values represent maximum allowed percentage unless otherwise noted.

Physical Properties

Material form, density, and contamination specifications.

Premium high-purity heavy copper scrap; solid form specification distinguishes from wire; direct smelter feedstock for heavy copper products

Acceptable Inclusions
  • Light oxidation/patina (green/blue from age)
  • Tight mechanical adhesion only
Prohibited Materials
  • Insulation (copper-insulated wire must be stripped)
  • Solder or solder coating
  • Paint or varnish
  • Zinc plating or other coatings
  • Brass or copper alloys >1%
  • Zinc >0.5% (brass contamination)
  • Lead >0.05% (critical)
  • Non-ferrous >0.1% individual
  • Ferrous attachments (must remove)
  • Radioactive materials
  • PCB or hazardous electronics
  • Asbestos

Quality Assurance

Testing protocols, sampling methods, and acceptance criteria.

Sampling Protocol
frequencyRandom selection including thickness verification
maximumQuantity100+ samples per large shipment
minimumQuantity2–5 tonnes or 50–100 samples
notesHeavy copper; thickness specification adds sampling requirement
percentage15–25% of lot
Acceptance Limits
all Criteria Must Passincluding thickness minimum
copper ContentCu ≥99.0%
iron LimitFe <0.1%
lead LimitPb <0.05%
nickel LimitNi <0.1%
thickness Minimumpieces ≥1/16 inch -
tin LimitSn <0.1%
visual Contaminantsinsulation, solder, paint, coating
zinc LimitZn <0.5%
Weight Tolerance
variance±2% from purchase order weight

Required Test Methods

Visual Inspection 100%

Method 1
Purpose
  • Confirm bare bright + verify minimum 1/16 inch thickness
Acceptance Criteria
  • Pass: Clean bright surface
  • NO insulation, solder, paint
  • ALL pieces ≥1/16" thick
Procedure
  • 100% visual scan
  • thickness verification on representative pieces

Thickness Measurement

Method 2
Purpose
  • Verify minimum 1/16 inch (1.6mm) requirement
Acceptance Criteria
  • Pass: All measured thickness ≥1/16 inch

XRF Spectrometry

Method 3
Purpose
  • Verify Cu ≥99%, Zn <0.5%, Pb <0.05%, Ni <0.1%, Fe <0.1%
Acceptance Criteria
  • Pass: Cu 99–100%
  • all contaminants within limits

Acid Test / Density Test

Method 4
Purpose
  • Rapid copper purity verification
Acceptance Criteria
  • Pass: Copper responds correctly
  • no coatings

Fire Assay

Method 5
Purpose
  • Precise purity certification (highest accuracy)
Acceptance Criteria
  • Pass: Cu ≥99.0%, Pb <0.05%
Cookie Notice

We use cookies to enhance your browsing experience.