ScrapBull
Marketplace/Non-Ferrous Copper/Bare Bright Copper
Bare Bright Copper
Non-Ferrous Copper

Bare Bright Copper

Grade: Barley/Berry (#1 Copper)Very High Tier

Clean, uncoated copper wire, #1 grade, 99%+ pure, no insulation

Market Price EstimateUpdated Daily
$3,780/ MT
+280 (8%)vs yesterday
Verified specifications & market data

Chemical Composition

Elemental breakdown by percentage weight.

Standard composition limits
Values represent maximum allowed percentage unless otherwise noted.

Physical Properties

Material form, density, and contamination specifications.

Premium high-purity copper scrap; bare bright classification; direct smelter feedstock for electrolytic refining

Acceptable Inclusions
  • Light oxidation/patina (green/blue from age)
  • Tight mechanical adherence only
Prohibited Materials
  • Insulation (PVC, rubber - any plastic)
  • Solder joints or solder coating
  • Paint or varnish coating
  • Zinc plating or other coatings
  • Fusion (bonded material)
  • Brass or other copper alloys >1%
  • Zinc >0.5% (brass contamination)
  • Lead >0.05% (critical contamination)
  • Non-ferrous metals >0.1% individual
  • Ferrous (steel) attachments must be removed
  • Radioactive materials
  • PCB or hazardous electronics
  • Asbestos materials

Quality Assurance

Testing protocols, sampling methods, and acceptance criteria.

Sampling Protocol
frequencyRandom selection from different sections of load
maximumQuantity100+ samples per large shipment
minimumQuantity2–5 tonnes or 50–100 samples
notesHigh-value material; extensive testing required for purity verification
percentage15–25% of lot
Acceptance Limits
all Criteria Must Passcriteria must be met; purity non-negotiable for premium grade
copper ContentCu ≥99.0%
iron LimitFe <0.1%
lead LimitPb <0.05%
nickel LimitNi <0.1%
oxygen LimitO₂ <0.05%
tin LimitSn <0.1%
visual Contaminantsinsulation, solder, paint, coating
zinc LimitZn <0.5%
Weight Tolerance
variance±2% acceptable from purchase order weight

Required Test Methods

Visual Inspection 100%

Method 1
Purpose
  • Confirm bare bright appearance (no insulation, solder, coating, paint)
Acceptance Criteria
  • Pass: Clean bright surface
  • no plastic, solder, paint visible
  • any insulation=REJECTION
Procedure
  • 100% visual inspection
  • any coated wire = immediate rejection

XRF Spectrometry

Method 2
Purpose
  • Verify Cu ≥99%, Zn <0.5%, Pb <0.05%, Ni <0.1%, Fe <0.1%
Acceptance Criteria
  • Pass: Cu 99–100%, contaminants within strict limits

Acid Test / Density Test

Method 3
Purpose
  • Rapid verification of copper purity (acid test confirms copper without insulation)
Acceptance Criteria
  • Pass: Copper reacts correctly
  • no plastic residue

Fire Assay

Method 4
Purpose
  • Precise copper/contaminant determination (highest accuracy for premium material)
Acceptance Criteria
  • Pass: Cu ≥99.0% confirmed
  • Pb <0.05% confirmed

Oxygen Determination / LECO Analysis

Method 5
Purpose
  • Verify oxygen <0.05% (electrical conductivity requirement)
Acceptance Criteria
  • Pass: O₂ <0.05%