ScrapBull
Marketplace/Specialty Scrap/Compressors (HVAC)
Compressors (HVAC)
Specialty Scrap

Compressors (HVAC)

Grade: VariousMedium Tier

Air conditioning and refrigeration compressors with copper

Market Price EstimateUpdated Daily
$1,450/ MT
+65 (4.7%)vs yesterday
Verified specifications & market data

Chemical Composition

Elemental breakdown by percentage weight.

Standard composition limits
Values represent maximum allowed percentage unless otherwise noted.

Physical Properties

Material form, density, and contamination specifications.

End-of-life HVAC compressors; cooling equipment decommissioning; MODERATE precious metal content (18-35% copper primary; 45-60% steel + 8-20% aluminum secondary); MODERATE hazmat complexity (refrigerant recovery EPA-required; compressor oil disposal cost; refrigeration compliance stringent); SUBSTANTIAL supplier diversity (267 suppliers; HVAC ubiquity); MEDIUM value commodity; copper recovery valuable; steel + aluminum significant; EPA refrigerant recovery required; HVAC recycling mature infrastructure; environmental compliance mandatory

Acceptable Inclusions
  • Copper 18-35% (compressor specification)
  • Steel 45-60% (commodity value)
  • Aluminum 8-20% (secondary valuable metal)
  • Refrigerant oil 2-8% (hazmat disposal acceptable if EPA recovery performed)
  • Dust, oxidation (post-service typical)
Prohibited Materials
  • Copper <18% (below specification)
  • Unrecovered refrigerant (EPA violation; hazmat critical)
  • Extreme contamination or hazard
  • Unknown composition or hazmat status

Quality Assurance

Testing protocols, sampling methods, and acceptance criteria.

Sampling Protocol
frequencyStratified sampling by compressor type; composition verification; refrigerant recovery documentation critical
maximumQuantity200+ compressors per shipment
minimumQuantity5-20 compressors or 100-500 kg
percentage8-12% of lot
stratificationSample across compressor types; capacities; ages; triple-metal composition variable by model; recovery protocol verification
Acceptance Limits
all Criteria Must PassCompressor be type; recovery ; triple-metal composition ; hazmat
aluminum ContentAluminum 8-20% confirmed; fins/components identified; secondary value
compressor AuthenticityConfirmed as compressor; type/capacity clearly identifiable; triple-metal composition predictable
contamination AcceptableNormal post-service contamination acceptable; extreme contamination for processing impact
copper ContentCopper 18-35% verified; tubing present and identifiable; primary metal value
epa Refrigerant Recoveryrefrigerant recovery ; recovery certificate provided; / protocols confirmed; hazmat
oil StatusOil residue documented; disposal method ; hazmat protocol
steel ContentSteel 45-60% confirmed; casing/motor housing significant; commodity basis
Weight Tolerance
measurementVerified by certified scale; weight accountability for triple-metal commodity
variance±5% from expected weight

Required Test Methods

Visual HVAC Compressor Type Assessment

CRITICALMANDATORY
Method 1
Purpose
  • identify compressor type (reciprocating/rotary/scroll/hermetic)
  • estimate capacity/tonnage
  • predict copper/aluminum/steel content
Acceptance Criteria
  • Compressor type clearly identifiable
  • capacity/tonnage determined
  • triple-metal content predictable from type
Procedure
  • 100% visual inspection
  • identify compressor markings/model number
  • determine type from design
  • assess capacity (residential 1-2 tons to commercial 10+ tons)
  • predict metal composition from type/capacity

EPA Refrigerant Recovery Certificate Verification

CRITICALABSOLUTEMANDATORY
Method 2
Purpose
  • verify EPA refrigerant recovery performed BEFORE compressor receipt
  • confirm CFC/HCFC recovery certification
  • establish hazmat clearance
Acceptance Criteria
  • EPA refrigerant recovery certificate provided
  • recovery technician EPA-certified
  • refrigerant type documented
  • zero residual refrigerant
  • hazmat cleared
Procedure
  • Documentation review
  • EPA recovery certificate verification
  • CFC/HCFC recovery protocols confirmed
  • recovered refrigerant quantity documented
  • reclamation/disposal method verified
  • EPA compliance

Copper Tubing Verification

CRITICAL
Method 3
Purpose
  • verify copper tubing present and intact (18-35% typical)
  • confirm high-quality refrigeration copper
  • establish primary value component
Acceptance Criteria
  • Copper tubing confirmed 18-35% range
  • tubing visible and identifiable
  • copper specifications
Procedure
  • Visual copper tubing assessment
  • identify tubing diameter/gauge
  • confirm clean copper (refrigeration grade)
  • estimate copper percentage
  • value basis confirmed

Aluminum Component Assessment

Method 4
Purpose
  • Verify aluminum fins/components present (8-20% typical)
  • confirm secondary metal value
  • establish recovery yield
Acceptance Criteria
  • Aluminum fins confirmed 8-20% range
  • aluminum components identified
  • secondary value
Procedure
  • Visual aluminum assessment
  • identify fin density/configuration
  • estimate aluminum percentage
  • corrosion assessment minimal/acceptable

Steel Casing Evaluation

Method 5
Purpose
  • Verify steel casing/motor housing (45-60% typical)
  • confirm commodity base metal value
  • establish bulk metal basis
Acceptance Criteria
  • Steel casing confirmed 45-60% range
  • ferrous component significant
  • commodity basis
Procedure
  • Visual steel assessment
  • identify casing construction
  • magnetic test confirmation
  • estimate steel percentage

Compressor Oil Assessment

Method 6
Purpose
  • Assess compressor oil residue (2-8% typical)
  • confirm disposal plan
  • establish hazmat handling protocol
Acceptance Criteria
  • Oil residue visible or documented
  • disposal method established
  • occupational handling protocol
Procedure
  • Visual oil assessment
  • identify oil type/condition
  • estimate oil percentage
  • disposal method confirmed (typically industrial waste facility)

Contamination Check

Method 7
Purpose
  • Assess dust, corrosion, environmental contamination
  • confirm material processable
  • establish handling protocol
Acceptance Criteria
  • Normal post-HVAC service contamination acceptable (dust, outdoor corrosion typical)
  • extreme contamination
Procedure
  • Visual contamination assessment
  • corrosion level evaluation
  • dust/environmental damage assessment
  • processing impact
Cookie Notice

We use cookies to enhance your browsing experience.