ScrapBull
Marketplace/Non-Ferrous Copper/Insulated Copper Wire #1
Insulated Copper Wire #1
Non-Ferrous Copper

Insulated Copper Wire #1

Grade: Druid (Clean Insulated Wire)High Tier

Clean copper wire with plastic/rubber insulation, 85%+ copper recovery

Market Price EstimateUpdated Daily
$2,950/ MT
+125 (4.4%)vs yesterday
Verified specifications & market data

Chemical Composition

Elemental breakdown by percentage weight.

Standard composition limits
Values represent maximum allowed percentage unless otherwise noted.

Physical Properties

Material form, density, and contamination specifications.

Insulated copper wire scrap; standard building/electrical wire with intact insulation; wire stripping feedstock; premium insulated grade

Acceptable Inclusions
  • Intact plastic/rubber insulation (defining feature)
  • Minor insulation wear/aging
  • Light discoloration from age
Prohibited Materials
  • Bare copper (missing insulation; different grade)
  • Solder joints or heavy coating
  • Paint or varnish on insulation
  • Mixed materials (copper + aluminum + steel)
  • Stainless steel mixing
  • Lead-based insulation (hazmat)
  • Asbestos insulation (hazmat)
  • PCB components attached
  • Radioactive materials

Quality Assurance

Testing protocols, sampling methods, and acceptance criteria.

Sampling Protocol
frequencyRandom selection from different wire types/sources
maximumQuantity50–75 samples per load
minimumQuantity1–2 tonnes or 30–40 samples
notesInsulated grade; copper recovery yield important
percentage10–15% of lot
Acceptance Limits
all Criteria Must PassIntact insulation + 85%+ recovery + clean source
cleanlinessMinimal contamination; no solder, paint, hazmat
copper Recovery≥85% copper recovery potential
hazardous Insulationlead-based, asbestos insulation
insulation Integrityinsulation
Weight Tolerance
variance±3% from purchase order weight

Required Test Methods

Visual Inspection 100%

Method 1
Purpose
  • Confirm insulation intact
  • assess cleanliness
  • exclude hazmat
Acceptance Criteria
  • Pass: Intact plastic/rubber insulation
  • minimal contamination
  • no hazmat
Procedure
  • 100% visual scan
  • confirm no bare copper, solder, paint

Insulation Quality Assessment

Method 2
Purpose
  • Confirm insulation suitable for stripping (not heavily deteriorated)
Acceptance Criteria
  • Pass: Insulation intact
  • minor wear acceptable
Procedure
  • Sample manual inspection
  • assess cracking/deterioration

Wire Stripping Test

Method 3
Purpose
  • Verify 85%+ copper recovery yield from insulation removal
Acceptance Criteria
  • Pass: Copper recovery ≥85%

XRF on Stripped Copper

Method 4
Purpose
  • Verify copper purity after insulation removal
Acceptance Criteria
  • Pass: Cu 85–95% minimum
  • Zn <1%, Pb <0.1%
Procedure
  • Strip samples
  • test bare copper for contaminants
Cookie Notice