.jpg&w=3840&q=75)
Non-Ferrous Magnesium
Magnesium Scrap
Grade: WalnutMedium-High Tier
Clean magnesium scrap and clippings
Market Price EstimateUpdated Daily
$2,850/ MT
+175 (6.5%)vs yesterday
Verified specifications & market data
Acceptable Packaging
Standard shipping configurations and containment requirements.
Nitrogen-filled sealed metal cans
0.5-1 tonne per can (weight-limited for fire safety; smaller batches critical)
Material
- Metal Cans With Nitrogen Purge
- Sealed Caps
- Dry-Pack Material Inside
- No Oxygen Exposure
Handling
- Hazmat Shipping Protocols
- Dangerous Goods Documentation Mandatory
- Specialized Logistics
- Certified Handlers Only
Notes
- Primary Magnesium Packaging
- Fire Hazard Class 4
- Inert Atmosphere Non-Negotiable
- Water/Moisture Absolutely Prohibited
Sealed metal drums
1-2 tonnes per drum (INERT ATMOSPHERE CRITICAL; fire safety weight limit)
Material
- Metal Drums With Nitrogen Atmosphere Seal
- Dry Mineral Packing Inside
- Hermetic Sealing
Handling
- Hazmat Protocols Mandatory
- Dangerous Goods Documentation Essential
- Specialized Transport
- Class 4 Flammable Compliance
Notes
- Standard Professional Magnesium Recycling Container
- Class 4 Fire Hazard
- Inert Atmosphere Preservation Critical
Specialized magnesium transport containers
2-5 tonnes per container (INERT ATMOSPHERE; fire suppression systems integrated)
Material
- Magnesium-Certified Containers
- Nitrogen Environment Sealed
- Integrated Safety Features
- Fire Containment Capability
Handling
- Hazmat Transport Protocols
- Class 4 Flammable Compliance
- Specialized Vehicle
- Trained Hazmat Driver Required
Protection
- Fire Suppression Integration
- Oxygen Exclusion Systems
- Emergency Containment Capability
Notes
- Ultra-Specialized Magnesium Transport Container
- Inert Atmosphere Maintained
- Integrated Fire Safety Systems
- Professional Hazmat Standard
Bulk sealed truck
10-15 tonnes per load (weight-limited for safety; highest volume but fire risk managed)
Material
- Specialized Sealed Truck Bed With Nitrogen Atmosphere
- Dry-Pack Internal
- Integrated Fire Suppression Capability
Handling
- Dot Class 4 Flammable Certification Mandatory
- Hazmat Driver Training Required
- Class 4 Vehicle Designation
- Specialized Logistics
Notes
- Economy Scale Magnesium Transport
- Class 4 Flammable Protocols Maximum
- Inert Atmosphere Maintained Throughout Transport
- Professional Hazmat Logistics Mandatory
Storage Requirements
Environmental controls, security protocols, and handling guidelines.
Environment
- nitrogen or argon atmosphere
- <1% oxygen NON-NEGOTIABLE
- Class 4 Flammable protocols establishment CRITICAL
Weather Protection
- fire-hazard material
- environmental protection extreme
- sealed containment necessary
Duration
- oxidation, water absorption, fire risk escalation
Humidity Control
Standard
- desiccant-based storage
- absolute dryness <100 ppm water NON-NEGOTIABLE
- humidity >30% increases hazard
Temperature Control
practical
- <20°C Optimal
- Climate Control Helps Stability
requirement
- Elevated Temperature Increases Reactivity
- Combustion Risk Escalates Above 30°C
- <20°C Optimal For Stability
Ventilation
practical
- Desiccated Air Circulation Acceptable
- Humidity-Controlled Ventilation
- Absolute Exclusion Of Humid/Wet Air
requirement
- Ventilation Systems Beneficial For Heat Management
- Ensure No Moisture-Carrying Humid Air Circulation
- Dry-Air Only Critical
Documentation
requirement
- Fire-Hazard Class 4 Status
- Inert Atmosphere Maintenance Logs
- Moisture Verification
- Emergency Protocols
- Chain-Of-Custody
- Insurance Compliance
storage
- Fire-Hazard Documentation Prominently Visible
- Class 4 Classification Posted
- Inert Atmosphere Monitoring Records Maintained
- Moisture Verification Certificates
- Emergency Contact Information
- Professional Compliance Verification
Security
access
- Restricted Access
- Trained Personnel Only
- 24/7 Monitoring Recommended
- Emergency Response Team On-Call
- No Unauthorized Personnel
facility
- Magnesium Class 4 Fire-Hazard
- Fire/Explosion Catastrophic Property Damage
- Professional Liability Extreme
Inspection Schedule
checkpoints
- Nitrogen Atmosphere Maintained (<1% Oxygen; Inert Gas Verification Continuous)
- Moisture Levels Monitored (Humidity Sensors Active; <10% Rh Maintained; Desiccant Systems Operational)
- Container Seal Integrity (Visual Verification; Hermetic Sealing Confirmed; No Compromises Acceptable)
- Temperature Stability (Monitoring Systems Operational; <20°C Optimal; Thermal Cycles Prevented)
- Fire Suppression Ready (Powder Extinguishers Accessible; Emergency Systems Tested; No Water Systems Present)
- Complete Segregation (Isolated From All Other Materials; No Proximity To Water; Fire Containment Systems Ready)
- Emergency Protocols (Procedures Posted; Staff Trained; Emergency Response Number Visible; Incident History Monitored)
- Documentation Current (Inert Atmosphere Logs Updated; Moisture Records Maintained; Emergency Protocols Reviewed; Insurance Compliance Verified)
- Professional Compliance (Magnesium Storage Standards Followed; Fire-Safety Protocols Operational; Regulatory Requirements Met)
frequency
- Class 4 Flammable Material
- Fire-Hazard Monitoring Critical
- Moisture Detection Paramount
- Safety Non-Negotiable