ScrapBull
Aluminum Radiators
Non-Ferrous Aluminum

Aluminum Radiators

Grade: TallyMedium-High Tier

All-aluminum automotive and HVAC radiators

Market Price EstimateUpdated Daily
$2,050/ MT
+105 (5.4%)vs yesterday
Verified specifications & market data

Chemical Composition

Elemental breakdown by percentage weight.

Standard composition limits
Values represent maximum allowed percentage unless otherwise noted.

Physical Properties

Material form, density, and contamination specifications.

Post-consumer aluminum scrap; end-of-life automotive radiators and HVAC heat exchangers; complete radiator assemblies or separated core components; specialized processing required; restricted copper contamination for aluminum purity

Acceptable Inclusions
  • Coolant residue <2% (typical automotive service residue)
  • Oil residue minimal (light)
  • Solder residue <1% (radiator assembly standard)
  • Light oxidation and corrosion
  • Dust and dirt from storage
  • Aluminum 90-98% (radiator specification)
  • Silicon <3% (alloy component)
  • Iron <1.5% (ferrous tolerance)
Prohibited Materials
  • Copper >1.0% (CRITICAL; must be all-aluminum radiators)
  • Copper-tube radiators (brass/copper brazed construction; excluded)
  • Mixed material radiators (non-aluminum components)
  • Lead solder >0.3% (minimal acceptable; excess restricted)
  • Ferrous radiators or steel contamination (>1.5% iron)
  • Stainless steel mixing
  • Heavy coolant saturation (>3%)
  • Unknown radiator type or composition

Quality Assurance

Testing protocols, sampling methods, and acceptance criteria.

Sampling Protocol
frequencyRandom stratified sampling from multiple positions in shipment
maximumQuantity75-100 samples per shipment
minimumQuantity0.5-1 tonne or 15-25 radiator units
percentage8-12% of lot
stratificationSample across radiator types if mixed in single lot
Acceptance Limits
all Criteria Must PassMaterial must be all-aluminum radiators; copper ≤1.0% ; radiator type identified
aluminum ContentAl 90-98%
coolant LevelCoolant <2%
copper LimitCu ≤1.0%
iron LimitFe <1.5%
magnetic TestNon-magnetic
material IdentityConfirmed all-aluminum radiators
radiator TypeConfirmed all-aluminum construction
solder LimitSolder <1%
Weight Tolerance
measurementVerified by certified scale; weight certificate required for lots >2 tonnes
variance±4% from purchase order weight

Required Test Methods

Visual Inspection

Method 1
Purpose
  • Confirm all-aluminum radiators (NOT copper-tube)
  • verify no mixed-metal contamination
  • assess condition
Acceptance Criteria
  • Radiators appear aluminum (silver)
  • no visible copper tubes/cores
  • no brass or reddish materials
  • construction identified
Procedure
  • 100% visual of all samples
  • verify radiator type (automotive vs. HVAC)
  • confirm aluminum construction
  • no copper-tube mixing

Magnetic Test

Method 2
Purpose
  • Exclude ferrous contamination or steel radiator mixing
  • verify non-magnetic aluminum
Acceptance Criteria
  • Non-magnetic (aluminum expected)
  • no strong ferrous attraction
Procedure
  • Magnet test on sample radiators
  • ferrous materials apparent
  • strong response triggers investigation

Copper Contamination Verification

CRITICAL
Method 3
Purpose
  • confirm copper ≤1.0%
  • exclude mixed-copper radiators
  • verify all-aluminum spec
Acceptance Criteria
  • No visible copper tubes/cores
  • XRF confirms Cu ≤1.0%
  • all-aluminum radiator confirmed
Procedure
  • Visual inspection for copper tubes
  • XRF copper analysis mandatory
  • confirm single-aluminum construction

Radiator Type Identification

Method 4
Purpose
  • Identify radiator type (automotive engine, transmission cooler, HVAC)
  • confirm processing compatibility
Acceptance Criteria
  • Radiator type identified (automotive or HVAC)
  • all-aluminum construction confirmed
Procedure
  • Visual identification of radiator form, size, attachment points
  • HVAC vs. automotive differentiation

Coolant Residue Assessment

Method 5
Purpose
  • Evaluate coolant contamination
  • assess draining adequacy
  • document for processing protocols
Acceptance Criteria
  • Coolant residue <2%
  • adequate draining confirmed
  • no heavy saturation
Procedure
  • Visual/olfactory assessment
  • identify coolant presence
  • confirm draining status

XRF Spectrometry

CRITICALMANDATORY
Method 6
Purpose
  • Verify Al 90-98%, confirm Cu ≤1.0% (), assess all contamination
Acceptance Criteria
  • Al 90-98%, Cu ≤1.0% (), Fe <1.5%, all others acceptable