.jpg&w=3840&q=75)
Non-Ferrous Aluminum
Aluminum Radiators
Grade: TallyMedium-High Tier
All-aluminum automotive and HVAC radiators
Market Price EstimateUpdated Daily
$2,050/ MT
+105 (5.4%)vs yesterday
Verified specifications & market data
Chemical Composition
Elemental breakdown by percentage weight.
Standard composition limits
Values represent maximum allowed percentage unless otherwise noted.
Physical Properties
Material form, density, and contamination specifications.
Post-consumer aluminum scrap; end-of-life automotive radiators and HVAC heat exchangers; complete radiator assemblies or separated core components; specialized processing required; restricted copper contamination for aluminum purity
Acceptable Inclusions
- Coolant residue <2% (typical automotive service residue)
- Oil residue minimal (light)
- Solder residue <1% (radiator assembly standard)
- Light oxidation and corrosion
- Dust and dirt from storage
- Aluminum 90-98% (radiator specification)
- Silicon <3% (alloy component)
- Iron <1.5% (ferrous tolerance)
Prohibited Materials
- Copper >1.0% (CRITICAL; must be all-aluminum radiators)
- Copper-tube radiators (brass/copper brazed construction; excluded)
- Mixed material radiators (non-aluminum components)
- Lead solder >0.3% (minimal acceptable; excess restricted)
- Ferrous radiators or steel contamination (>1.5% iron)
- Stainless steel mixing
- Heavy coolant saturation (>3%)
- Unknown radiator type or composition
Quality Assurance
Testing protocols, sampling methods, and acceptance criteria.
Sampling Protocol
frequencyRandom stratified sampling from multiple positions in shipment
maximumQuantity75-100 samples per shipment
minimumQuantity0.5-1 tonne or 15-25 radiator units
percentage8-12% of lot
stratificationSample across radiator types if mixed in single lot
Acceptance Limits
all Criteria Must PassMaterial must be all-aluminum radiators; copper ≤1.0% ; radiator type identified
aluminum ContentAl 90-98%
coolant LevelCoolant <2%
copper LimitCu ≤1.0%
iron LimitFe <1.5%
magnetic TestNon-magnetic
material IdentityConfirmed all-aluminum radiators
radiator TypeConfirmed all-aluminum construction
solder LimitSolder <1%
Weight Tolerance
measurementVerified by certified scale; weight certificate required for lots >2 tonnes
variance±4% from purchase order weight
Required Test Methods
Visual Inspection
Purpose
- Confirm all-aluminum radiators (NOT copper-tube)
- verify no mixed-metal contamination
- assess condition
Acceptance Criteria
- Radiators appear aluminum (silver)
- no visible copper tubes/cores
- no brass or reddish materials
- construction identified
Procedure
- 100% visual of all samples
- verify radiator type (automotive vs. HVAC)
- confirm aluminum construction
- no copper-tube mixing
Magnetic Test
Purpose
- Exclude ferrous contamination or steel radiator mixing
- verify non-magnetic aluminum
Acceptance Criteria
- Non-magnetic (aluminum expected)
- no strong ferrous attraction
Procedure
- Magnet test on sample radiators
- ferrous materials apparent
- strong response triggers investigation
Copper Contamination Verification
CRITICAL
Purpose
- confirm copper ≤1.0%
- exclude mixed-copper radiators
- verify all-aluminum spec
Acceptance Criteria
- No visible copper tubes/cores
- XRF confirms Cu ≤1.0%
- all-aluminum radiator confirmed
Procedure
- Visual inspection for copper tubes
- XRF copper analysis mandatory
- confirm single-aluminum construction
Radiator Type Identification
Purpose
- Identify radiator type (automotive engine, transmission cooler, HVAC)
- confirm processing compatibility
Acceptance Criteria
- Radiator type identified (automotive or HVAC)
- all-aluminum construction confirmed
Procedure
- Visual identification of radiator form, size, attachment points
- HVAC vs. automotive differentiation
Coolant Residue Assessment
Purpose
- Evaluate coolant contamination
- assess draining adequacy
- document for processing protocols
Acceptance Criteria
- Coolant residue <2%
- adequate draining confirmed
- no heavy saturation
Procedure
- Visual/olfactory assessment
- identify coolant presence
- confirm draining status
XRF Spectrometry
CRITICALMANDATORY
Purpose
- Verify Al 90-98%, confirm Cu ≤1.0% (), assess all contamination
Acceptance Criteria
- Al 90-98%, Cu ≤1.0% (), Fe <1.5%, all others acceptable