ScrapBull
Aluminum Siding
Non-Ferrous Aluminum

Aluminum Siding

Grade: TaleMedium Tier

Painted aluminum house siding and gutters

Market Price EstimateUpdated Daily
$1,950/ MT
+85 (4.6%)vs yesterday
Verified specifications & market data

Chemical Composition

Elemental breakdown by percentage weight.

Standard composition limits
Values represent maximum allowed percentage unless otherwise noted.

Physical Properties

Material form, density, and contamination specifications.

Post-consumer aluminum building material scrap; residential/commercial siding and gutter systems; painted architectural aluminum; building demolition/renovation source; paint removal processing required; significant hazmat risk (lead paint, VOCs); established building waste recycling stream

Acceptable Inclusions
  • Paint coating 5-15% (defining characteristic)
  • Acrylic, polyester, vinyl, enamel paint types
  • Paint adhesion varying (thick or thin acceptable)
  • Light oxidation (hidden under paint)
  • Weathering from outdoor exposure
Prohibited Materials
  • Aluminum <90% core (insufficient metal content)
  • Lead-based paint >5% (hazmat; pre-treatment verification)
  • Asbestos in older coatings (pre-1980s risk)
  • PCB-containing paint
  • Ferrous/stainless steel contamination
  • Unknown paint composition or age
  • Friable paint or contamination hazard

Quality Assurance

Testing protocols, sampling methods, and acceptance criteria.

Sampling Protocol
frequencyRandom stratified sampling from multiple shipment positions
maximumQuantity150-200 samples per shipment
minimumQuantity1-2 tonnes or 50-100 siding panel samples
percentage10-15% of lot
stratificationSample across siding colors/types/apparent ages if mixed in single lot
Acceptance Limits
all Criteria Must PassMaterial must be aluminum siding; paint documented; hazmat status determined; lead/asbestos assessment completed
aluminum ContentAl 90-99%
asbestos Statusor risk documented; friable asbestos =
building EraConstruction period documented; pre-1978 = presumed lead risk
iron LimitFe <0.5%
lead Statusbe assessed: lead-free lead-based with documented ppm
paint CoatingPaint 5-15% by weight
paint TypeIdentified as acrylic, polyester, enamel, or known composition
Weight Tolerance
measurementVerified by certified scale; weight certificate required for lots >2 tonnes
variance±5% from purchase order weight

Required Test Methods

Visual Inspection

Method 1
Purpose
  • Confirm aluminum siding (not ferrous)
  • assess paint condition
  • detect hazmat indicators
Acceptance Criteria
  • Aluminum siding apparent
  • paint coating visible
  • no ferrous contamination
  • building era/color identifiable
Procedure
  • 100% visual of all samples
  • verify aluminum appearance
  • assess paint color/condition
  • identify siding type
  • note any obvious hazard indicators

Magnetic Test

Method 2
Purpose
  • Exclude ferrous/stainless contamination
  • verify aluminum non-magnetic
Acceptance Criteria
  • Non-magnetic (aluminum expected)
  • no strong ferrous attraction
Procedure
  • Magnet test on sample siding pieces
  • no ferrous response expected

Building Age & Era Assessment

CRITICAL
Method 3
Purpose
  • determine building construction period
  • assess lead paint probability
Acceptance Criteria
  • Building era documented
  • pre-1978 = presumed lead risk
  • post-1978 = lead-free assumption
Procedure
  • Historical building assessment if available (address research)
  • visual era indicators
  • document construction period

Lead Paint Screening

CRITICAL
Method 4
Purpose
  • detect lead-based paint presence
  • trigger hazmat protocol if positive
Acceptance Criteria
  • Lead-free confirmed OR lead content assessed and documented

Asbestos Risk Assessment

CRITICAL
Method 5
Purpose
  • identify asbestos risk in older paint coatings
Acceptance Criteria
  • Asbestos-free confirmed OR risk assessment documented
  • no friable asbestos
Procedure
  • Visual inspection for friable/powdery coating (asbestos indicator)
  • pre-1980 materials flagged for potential asbestos

Paint Type Identification

Method 6
Purpose
  • Identify paint type (acrylic, polyester, enamel)
  • assess removal difficulty
  • determine processing requirements
Acceptance Criteria
  • Paint type identified
  • removal method compatibility determined
Procedure
  • Visual assessment of paint finish
  • adhesion test (scratch test)
  • paint type classification

Paint Coating Weight Analysis

Method 7
Purpose
  • Verify paint coating 5-15% by weight
  • assess processing loss expectations
Acceptance Criteria
  • Paint 5-15% by weight confirmed
  • within expected range

XRF Spectrometry

Method 8
Purpose
  • Analyze painted surface
  • detect lead in paint
  • identify paint contaminants (hazmat assessment)
Acceptance Criteria
  • Lead status determined (present/absent)
  • aluminum base confirmed after paint consideration
Procedure
  • Surface XRF identifies paint elements including lead
  • establishes hazmat status
  • hazmat protocol triggers if positive
Cookie Notice

We use cookies to enhance your browsing experience.