ScrapBull
Soft Lead Scrap
Non-Ferrous Lead

Soft Lead Scrap

Grade: RacksMedium Tier

Clean soft lead scrap, free of contamination

Market Price EstimateUpdated Daily
$2,150/ MT
+125 (6.2%)vs yesterday
Verified specifications & market data

Chemical Composition

Elemental breakdown by percentage weight.

Standard composition limits
Values represent maximum allowed percentage unless otherwise noted.

Physical Properties

Material form, density, and contamination specifications.

Post-industrial soft lead scrap; lead pipe, cable shielding, weights, roofing material, radiation shielding; minimal alloying; high-purity refining feedstock; established lead recycling stream; lead refining and battery production primary applications; hazmat material requiring strict protocols

Acceptable Inclusions
  • Lead 95-99.8% (pure soft lead specification)
  • Copper <2% (refining separation acceptable)
  • Zinc <1% (minimal galvanizing residue)
  • Iron <1% (ferrous contamination minimal)
  • Tin <0.5% (solder trace)
  • Light oxidation/patina
Prohibited Materials
  • Cadmium >0.01% (HAZMAT - toxic; strict limit)
  • Arsenic >0.01% (HAZMAT - toxic; strict limit)
  • Mixed metals (ferrous, stainless, aluminum mixing prohibited)
  • Contaminated or unidentified lead material
  • Lead from hazardous sources (hazmat batteries, radioactive)
  • Lead paint chips (hazmat concern)
  • Unknown lead composition

Quality Assurance

Testing protocols, sampling methods, and acceptance criteria.

Sampling Protocol
frequencysampling: pipes separate, cable shielding separate, battery clippings separate, industrial components separate; hazmat screening comprehensive
maximumQuantity100-150 samples per shipment
minimumQuantity1-2 tonnes or 50-100 soft lead samples
percentage10-15% of lot
Acceptance Limits
all Criteria Must PassMaterial must be soft lead ≥95%; copper <2%; hazmat ppm-level confirmed <0.01% both Cd/As; Racks specification
arsenic LimitArsenic <0.01% ppm-level
cadmium LimitCadmium <0.01% ppm-level
copper LimitCopper <2% acceptable
hazmat ClearedCadmium Arsenic both <0.01%
lead ContentLead 95-99.8% within specification
material IdentityConfirmed as soft lead
source VerificationLead source identified ; age assessed; hazmat risk classified
Weight Tolerance
measurementBulk weight acceptable; precision secondary; weight-constrained logistics
variance±2% from purchase order weight

Required Test Methods

100% Visual Inspection

CRITICALABSOLUTEMANDATORY
Method 1
Purpose
  • verify soft lead (not ferrous, not composite)
  • confirm clean form
  • assess contamination level visual
  • evaluate equipment vintage/modern
Acceptance Criteria
  • Soft lead apparent (characteristic lead form
  • gray color
  • extreme weight
  • softness)
  • clean specification visual
  • no obvious foreign material
  • Racks grade evident
Procedure
  • 100% visual inspection
  • verify lead character (gray metal
  • extreme density apparent
  • softness deformation easy)
  • confirm clean specification
  • identify source morphology (pipes, cable, castings)
  • assess equipment age vintage vs. modern

Magnetic Separation Test

CRITICALMANDATORY
Method 2
Purpose
  • verify non-ferrous character
  • exclude ferrous/steel mixing
  • confirm pure lead non-magnetic
Acceptance Criteria
  • Non-magnetic (lead expected absolute)
  • no ferrous attraction confirmed
  • soft lead pure metallic
Procedure
  • MAGNET TEST on sample
  • confirm lead non-ferrous character absolute
  • no ferrous attraction
  • verify pure metallic lead composition

Lead Source Assessment

Method 3
Purpose
  • determine lead source type (pipes vs. cable vs. battery vs. industrial)
  • assess age/equipment generation
  • estimate hazmat risk profile
Acceptance Criteria
  • Lead source identified
  • equipment age classification clear
  • hazmat risk assessed
Procedure
  • PHYSICAL EXAMINATION sample
  • identify source morphology (pipe threads, cable armor, battery posts)
  • assess manufacturing characteristics
  • determine vintage vs. modern generation
  • estimate source composition/hazmat risk

Hazmat Screening - Cadmium/Arsenic

CRITICALABSOLUTEEXTREMEZERO-TOLERANCEMANDATORY
Method 4
Purpose
  • detect cadmium AND arsenic ppm-level precision (legacy 1970s-1980s equipment risk variable)
  • assess occupational hazmat risk
  • worker safety paramount
Acceptance Criteria
  • Cadmium <0.01% ppm-level
  • Arsenic <0.01% ppm-level
  • occupational hazmat cleared
  • legacy equipment status
Procedure
  • ICP-AES ultra-sensitive quantification (ppm-level precision)
  • historical source age assessment (vintage vs. modern)
  • legacy hazmat risk evaluation
  • cadmium/arsenic detection comprehensive extreme ppm-level

XRF Spectrometry

MANDATORYEXTREME
Method 5
Purpose
  • quantify lead 95-99.8%, copper <2%
  • detect cadmium/arsenic ppm-level extreme
  • verify Racks specification
  • validate commercial value
Acceptance Criteria
  • Lead 95-99.8%
  • Copper <2% confirmed
  • Cadmium <0.01% extreme
  • Arsenic <0.01% extreme
  • soft lead specification
  • refining-grade confirmed
Procedure
  • XRF analysis MINIMUM 10-15 samples from different soft lead types/sources stratified
  • quantify lead/copper/cadmium/arsenic ppm-level
  • accuracy ±0.5% lead, ±0.005% Cd/As

Copper Alloy Assessment

Method 6
Purpose
  • quantify copper alloying element
  • assess if within <2% tolerance
  • determine if smelting separation required
Acceptance Criteria
  • Copper <2% confirmed acceptable
  • smelting separation economical
Procedure
  • XRF spectrometry copper quantification
  • assess copper percentage of total composition
  • determine if within Racks specification <2%
Cookie Notice

We use cookies to enhance your browsing experience.