ScrapBull
Marketplace/Ferrous/Stainless Steel 430
Stainless Steel 430
Ferrous

Stainless Steel 430

Grade: 430 (16/0 Ferritic)Medium Tier

Ferritic stainless, magnetic, 16-18% chrome, minimal nickel

Market Price EstimateUpdated Daily
$1,250/ MT
+45 (3.7%)vs yesterday
Verified specifications & market data

Chemical Composition

Elemental breakdown by percentage weight.

Standard composition limits
Values represent maximum allowed percentage unless otherwise noted.

Physical Properties

Material form, density, and contamination specifications.

Ferritic stainless steel scrap; MAGNETIC (differs from austenitic 304/316); cost-effective stainless alternative

Acceptable Inclusions
  • Surface oxidation and discoloration (ferritic typical)
  • Light grease/oil <1%
  • Paint coating (burns off)
  • Mill scale
Prohibited Materials
  • Austenitic stainless (304, 316 mixing with 430)
  • Carbon steel mixing (CRITICAL; 100% segregation)
  • Copper or brass components (non-ferrous)
  • Non-ferrous metals >0.5% each
  • Radioactive materials
  • PCB or hazardous electronics
  • Asbestos materials
  • Mercury components
  • Excessive nickel (>0.75% indicates grade mixing)

Quality Assurance

Testing protocols, sampling methods, and acceptance criteria.

Sampling Protocol
frequencyRandom selection from different material pieces
maximumQuantity40 samples per load
minimumQuantity1–2 tonnes or 20–30 samples
notesMagnetic test helps identify 430 vs. austenitic; ferritic more consistent than austenitic
percentage5–10% of lot
Acceptance Limits
all Criteria Must Passcriteria must be met; magnetic + Ni <0.75% especially critical
carbon LimitC <0.12%
chromium RangeCr 16.0–18.0%
iron RangeFe 80–88%
magnetic Responsemagnetic pull
molybdenumMo <0.1%
nickel LimitNi <0.75%
silicon RangeSi 1.0–2.0%
sulfur LimitS <0.03%
Weight Tolerance
variance±3% acceptable from purchase order weight

Required Test Methods

Magnetic Test

CRITICAL
Method 1
Purpose
  • Identify ferritic 430 (magnetic) vs. austenitic 304/316 (non-magnetic)
Acceptance Criteria
  • Pass: STRONG magnetic response (ferritic 430 confirmed)
Procedure
  • Handheld magnet on every piece
  • strong pull = 430
  • no pull = austenitic (contamination)

XRF Spectrometry

CRITICAL
Method 2
Purpose
  • Verify Cr 16–18%, Ni <0.75% ( nickel limit), Fe 80–88%
Acceptance Criteria
  • Pass: Cr 16–18%, Ni <0.75% (MUST verify <0.75%), Fe within range

Combustion Analysis

Method 3
Purpose
  • Verify carbon <0.12%, sulfur <0.03%
Acceptance Criteria
  • Pass: C <0.12%, S <0.03%

Nickel Verification

Method 4
Purpose
  • Confirm nickel <0.75% (defines ferritic 430)
Procedure
  • XRF or ICP-AES must explicitly confirm Ni <0.75%
  • if >1.5% = austenitic contamination