ISO 9001:2015 Quality Management System
Scope

UBC collection, sorting, processing, baling, quality control, drying, moisture verification

Requirement

Supplier must maintain active ISO 9001 certification throughout contract term

Certification BodyAccredited third-party audit body
RenewalAnnual audit required; certification must remain current
Certificate of Analysis
Content
  • Aluminum content: ≥95% confirmed (UBC pure specification)
  • Iron content: <0.3% confirmed (ferrous contamination control)
  • Moisture content: <0.5% confirmed (CRITICAL - dry specification)
  • Paint/coating residue: <0.5% documented (label removal verification)
  • Organic residue: <0.3% documented (beverage residue confirmation)
  • Magnesium, copper, zinc: trace elements combined <1%
  • Ferrous material: non-magnetic confirmed (no steel contamination)
  • Bale condition: compressed stable form verified; no deterioration
  • Drying status: completely dry condition verified
  • No hazardous material or contamination detected
  • Clean consumer beverage can origin confirmed
Moisture & Dryness Certificate
Explicit Requirement

MUST state:

  • Moisture content verified <0.5%
  • UBC bales confirmed completely dry
  • ready for direct smelting
  • no moisture-related processing concerns
XRF Elemental Analysis Report
Requirement

Complete elemental profile confirming UBC beverage can aluminum specification

ISRI Taldon Grade Certification
Explicit Requirement

MUST state:

  • Aluminum UBC
  • ISRI Taldon Grade
  • Al ≥95%
  • clean dry condition confirmed
  • moisture <0.5%
  • non-ferrous verified
  • beverage can origin authenticated
Cleanliness Certification
Requirement

Documentation that material is clean beverage cans (not contaminated industrial scrap)

Insurance Certificate
Minimum Coverage
  • Commodity Aluminum
  • Consumer Recycling Material

Rejection Criteria

Conditions and thresholds that trigger immediate rejection or downgrading.

Moisture excess
Threshold

Moisture >0.5% OR visibly wet/damp bales

Action

FULL REJECTION or -£25-50/MT penalty

Reason
  • Critical: Moisture Degrades Smelter Efficiency
  • Ubc Dry Specification Violated
Test Method

Moisture meter analysis or loss-on-heating test (AUTHORITATIVE)

Severity

CRITICAL - SPECIFICATION VIOLATION (ABSOLUTE)

Consequence:
  • Automatic Rejection Unless -£25-50/Mt Penalty Accepted
  • Material Requires Re-Drying
Aluminum content below minimum
Threshold

Al <95%

Action

Full rejection or reclassification

Reason

Material purity below UBC consumer commodity specification

Test Method

XRF spectrometry

Severity

CRITICAL - SPECIFICATION VIOLATION

Consequence:

Full lot rejection or downgrading to lower grade

Ferrous cans or steel contamination
Threshold

Magnetic attraction detected OR Fe >0.3%

Action

Full rejection or magnetic separation required

Reason
  • Ferrous Mixing Violates Aluminum Ubc Specification
  • Steel Cans Incompatible
Test Method

Magnetic test + XRF spectrometry

Severity

CRITICAL - CONTAMINATION

Consequence:
  • Full Or Partial Rejection
  • Material Segregated Or Separated
Food waste or non-beverage contamination
Threshold

Food waste apparent OR organic material >0.5%

Action

Full rejection

Reason
  • Contamination Violates Clean Beverage Can Specification
  • Smelter Hazard
Test Method

Visual inspection + smell test + loss-on-ignition

Severity

CRITICAL - CONTAMINATION

Consequence:
  • Full Rejection
  • Material Disqualified From Ubc Commodity Tier
Heavy paint/label residue
Threshold

Paint >0.5% OR significant label material remaining

Action

Full rejection or stripping required

Reason
  • Labels Not Properly Removed
  • Coating Excess
Test Method

Visual inspection + thermal analysis

Severity

MODERATE-CRITICAL - PROCESSING

Consequence:

Rejection or reclassification to painted commodity

Mixed aluminum scrap
Threshold

Unknown aluminum alloys mixed in OR non-beverage source apparent

Action

Full rejection

Reason
  • Ubc Specification Requires Beverage Can Source
  • Mixed Alloys Unacceptable
Test Method

XRF alloy analysis + visual assessment

Severity

CRITICAL - MATERIAL TYPE VIOLATION

Consequence:
  • Full Rejection
  • Material Disqualified As Ubc Commodity
Stainless steel or exotic metal contamination
Threshold

>0.5% detected

Action

Full rejection

Reason

Non-aluminum contamination violates specification

Test Method

XRF spectrometry + visual inspection

Severity

CRITICAL - CONTAMINATION

Consequence:
  • Entire Lot Rejected
  • Material Segregated As Mixed Metal Scrap
Hazardous material contamination
Threshold

PCB, electronic components, or toxic substances detected

Action
  • Full Rejection
  • Hazmat Protocol If Required
Reason
  • Worker/Environmental Safety Violation
  • Operational Hazard
Test Method

Visual inspection + elemental analysis

Severity

CRITICAL - HAZMAT/SAFETY

Consequence:
  • Full Rejection